Canceller Operation - Teledyne QMultiFlex-400 Installation And Operating Handbook

Mcpc/scpc hub
Table of Contents

Advertisement

QMultiFlex-400™ Installation and Operating Handbook
QFlex-400 series Remote Modem Es/No can be noted from the
Record the measured levels within the table below to compare when the hub canceller is
enabled.
Remote Modem
Remote Modem 1
Remote Modem 2
Remote Modem 3
Remote Modem 4
Remote Modem 5
Remote Modem 6
Remote Modem 7
Remote Modem 8
Remote Modem 9
Remote Modem 10
Remote Modem 11
Remote Modem 12
Remote Modem 13
Remote Modem 14
Table 8-4 – Record Initial Hub and Remote Modem Es/No Values
8.3.4

Canceller Operation

The round-trip time is used to calculate the time offset between the Local TX signal and the
RX data containing the Near TX signal. The more accurately the earth station
latitude/longitude, and satellite longitude configuration, or actual round trip delay
parameters are entered, the faster the acquisition time will be. After initial acquisition, a
continuous 24-hour period is required for the software to determine and store an accurate
round-trip time. If using delay, check the canceller delay graphs to ensure the maximum
and minimum excursions accurately match the entered delay parameters. If need be, the
round-trip delay parameters can be honed to ensure optimum performance.
Figure 8-11 – QFlex-400 Status Screen
Hub Es/No
8-11
Status
screen:
Remote Es/No