6.2 Web User Interface

The modem includes an embedded web server that allows full monitoring and configuration
of the modem via a web browser (on port 80).
Secure connections via HTTPS (on port 443) are also supported. Non-secure connections
via HTTP (port 80) can optionally be disabled.
Google Chrome, Mozilla Firefox and Microsoft Internet Explorer web browsers are
supported.
6.2.1

Web GUI Login

If wanting to use the web GUI on a Q-MultiFlex-400™, the M&C IP address in the modem
will need to be set via the front panel. Press Main Key to ensure you are at the top menu
level:
The menu options are selectable by moving the cursor using the arrow buttons on the front
panel, then pressing enter on the option you would like. The faster method is just to press
the number associated with the option required e.g. above the Edit option can be selected
by simply pressing the '2' key.
The default IP address for all Teledyne Paradise Datacom modems is 10.0.70.1 / 16. To
change M&C IP address, press: Main, 2:Edit, 3:IP, 2: Addresses - on the front panel of the
Q-MultiFlex-400™. Use arrow keys and numerical keys to change values. Press the enter
button once the address is correct.
M&C IP Address:
[010.000.070.001]
[010.000.070.001]
Press enter again to go to the next screen. Edit the subnet mask. Press enter again to
move it to the top line 'applied' position.
Ensure your M&C PC is on the same subnet and connect a LAN cable to the M&C port of
the modem. The connection link LED should illuminate green on the IP port.
Pinging the modem M&C IP address should show replies.
[QMultiFlex-400]
1:Status
3:View
-------IP Traffic------
Link
M&C
Port
6-2
2:Edit
4:Test
M&C IP subnet mask:
[255.255.000.000]
[255.255.000.000]