Status Buc/Lnb Tab - Teledyne QMultiFlex-400 Installation And Operating Handbook

Mcpc/scpc hub
Table of Contents

Advertisement

QMultiFlex-400™ Installation and Operating Handbook
Transmit data rate. This is the instantaneous transmit data rate, which varies with
MODCOD (MODCOD is the shorthand term used to describe the combination of
modulation and FEC code rate).
Transmit MODCOD. This is the current transmit modulation and FEC rate, which
vary with remote Es/No.
Remote modem Es/No (energy per symbol to spectral noise density ratio).
Note: Demodulator information is not shown.
ACM operation is described in Section 8.2.

6.2.2.7 Status BUC/LNB Tab

If BUC or LNB services are enabled, then the Status BUC/LNB tab will be available.
Block Up Converter (BUC) / Low Noise Block (LNB) status is continually updated with the
following information:
BUC output*: This is the output power in dBm at the waveguide flange, or Off
when the BUC is not transmitting.
BUC temperature* This shows the temperature in degrees Centigrade reported by
the BUC.
BUC class* This shows the BUC power class in Watts.
BUC current: Shows the BUC current level in Amperes if a BUC PSU is installed
LNB voltage: Shows the LNB voltage in Volts when an LNB is connected.
LNB current: Shows the LNB current in milli-Amperes when an LNB is connected.
*Requires an FSK communications link to exist between the modem and the BUC.
Note: BUC and LNB under and over-current alarms can be controlled via the Edit->Unit-
>Alarms screen.
Figure 6-9 Status BUC/LNB Screen
6-9