QMultiFlex-400™ Installation and Operating Handbook
Figure 6-30 Edit->Unit->M&C->HTTPS Screen
Secure HTTPS connections to the modem's web server (on port 443) are always enabled.
However, it is possible to disable (and re-enable) standard HTTP requests (on port 80)
using this screen.
6.2.15
Edit->Unit->Alarms Screen
The Edit->Unit->Alarms screen is shown in Figure 6-31.
Figure 6-31 Edit->Unit->Alarms Screen

6.2.15.1 BUC DC Current Alarm

Even when there is no FSK communications path between the BUC and modem, it is still
possible for the modem to monitor the BUC for under/over current that causes the BUC to
overheat or become unstable. Table 6-32 describes how to set the BUC minimum and
maximum DC current levels outside of which a BUC DC current alarm will be raised if BUC
DC alarm enable is set.