8.8.4
QFlex-400™ Remote Configurations
The remote modems will be given the following M&C IP addresses:
Remote modem 1: 10.0.70.1 / 16
Remote modem 2: 10.0.70.2 / 16
Remote modem 3: 10.0.70.3 / 16
To change the M&C IP address, press: Main, 2:Edit, 3:IP, 2: Addresses
M&C IP Address:
[010.000.070.001]
[010.000.070.001]
Press enter again to go to the next screen. Edit the
subnet mask. Press enter again to move it to the top line position.
Do the same for remotes 2 and 3. It will now be possible to connect the PC (10.0.70.100) to
the modems M&C port using the addresses 10.0.70.1 to 10.0.70.3. Pinging the modem IP
address should show replies.
In a web browser type in the modem M&C address into the address bar.
Default credentials are:
Username: admin
Password: paradise
QMultiFlex-400™ Installation and Operating Handbook
Move cursor to the end of the line and enter '1' in the
last digit. Then press enter. The number will move to
the top line to
show
current value.
the
M&C IP subnet mask:
[255.255.000.000]
[255.255.000.000]
8-53