6.2.2.2 Status

The Status section (left-hand side of Figure 6-4) of the Status Summary page is continually
updated with the following information:
Transmit path status. When there is no transmit path fault then the message 'Tx
OK since HH:MM:SS on DD/MM/YY' is displayed (where 'HH' indicates hours,
'MM' indicates minutes, 'SS' indicates seconds, 'DD' indicates the day of the
month, 'MM' indicates the month of the year and 'YY' indicates the year). When a
transmit path fault exists, then a fault message is displayed instead that indicates
the nature of the fault.
Receive path status. When there is no receive path fault then the message 'Rx OK
since HH:MM:SS on DD/MM/YY' is displayed (where the time and date format is
as above). When a receive path fault exists, then a fault message is displayed
instead that indicates the nature of the fault.
IP Tx buffer fill status. This shows, as a percentage, how full the modem's transmit
buffer towards satellite is.
Receive composite power level (i.e. All of the power in the whole receive channel,
consisting of both wanted and unwanted signal).

6.2.2.3 Status AUPC

The Automatic Uplink Power Control (AUPC) section of the Status screen is displayed and
continually updated with the following information when AUPC is enabled:
Remote Eb/No. This is the current Eb/No reported by the remote modem.
Power offset. This is the current offset that has been applied to the nominal modem
power output level in order to maintain the remote Eb/No at the target level.

6.2.2.4 Status Ethernet Tab

The ethernet status tab shows the status of the base modem IP ports.
M&C port: Status should always be up if web GUI is connected to it.
IP1 = Main traffic port connected to IP processing card IP4 (should always be up if patch
cable is connected to IP processing card)
IP2 = Cascade port 1. Status is up if connected to another QMultiFlex-400™ cascade port.
IP3 = Cascade port 2. Status is up if connected to another QMultiFlex-400™ cascade port.
Figure 6-6 Ethernet Port Status