Scanner Unit (PL3.1.1)
Phaser 6115MFP Multifunction Product Service Manual
1.
Remove the Auto Document Feeder Unit (page 8-11).
2.
Remove the Rear Cover (page 8-6).
3.
Remove the Left Cover (page 8-7).
4.
Remove the Right Cover (page 8-8).
5.
Close the Top Cover and the Scanner lid.
6.
Remove the ADF Unit (page 8-11).
7.
Remove 11 screws (metal, 8mm), disconnect the connector P/J21, and
remove the Image Processing Board metal protective cover.
Note
Lift up on the metal hooks to remove.
Service Parts Disassembly
P/J21
s6115-426
8-25