Adjustments and Print Function Settings
6-54
Adjustment Range:
The default setting is 0.00.
Adjustment range: -4.00 (-4.00 mm) ~ "0.00 (0.00 mm)" ~ +4.00 (+4.00
mm)
Procedure:
1.
Prepare a chart (A4S or 11 x 8-1/2S) by drawing a reference line on a
sheet of paper at a position 20 mm away from the edge as illustrated on
the left.
2.
Load the chart in the Auto Document Feeder Unit and make five 1-sided
copies of the chart.
20 mm
3.
Align each copy sample as shown and check the deviation.
4.
If the deviation is outside the specified range, perform the adjustment
within the specification range of 0 ± 1.0 mm.
Phaser 6115MFP Multifunction Product Service Manual
s6115-364
s6115-365