Phaser 6115MFP Multifunction Product Service Manual
5.
Remove the springs from between the feed unit and the paper tray.
Caution
Use care not to lose the two springs. Also, be careful not to damage
the actuator of the Tray 1 No Paper Empty Sensor.
6.
Push in the tab that secures the housing to the frame.
7.
Release the tab of the sensor holder.
8.
Disconnect the 4-wire connector (P/J43), then release the plastic hooks to
remove the sensor.
Service Parts Disassembly
P/J43
s6115-338
s6115-507
8-119