CCD Main Regist
Phaser 6115MFP Multifunction Product Service Manual
5.
Use A4 or Letter paper loaded into tray1 to make the test copy.
6.
Check that the width of E in the copy of the test pattern 1 meets the
specification. Calculation: (1 - Width of E in the document ³ Width of E in
the copy) ¥ 100.
If the width of E is out of specification, adjust it according to the following
procedure:
a.
Press the Menu Select key.
b.
Using the p/q key, change the setting value and then press the Menu
Select key.
c.
Place the test pattern 1 on the Original Glass. Then, make a test copy
again and check it.
Adjustment Instructions:
If the width of E in the test pattern is longer than the specified width.....
Decrease the setting.
If the width of E in the test pattern is shorter than the specified width.....
Increase the setting.
Function:
To adjust for variations in the accuracy of Scanner parts and their mounting
accuracy by varying the scanning start position in the main scanning
direction.
Use:
When the original glass is replaced or when the Scanner unit has been
replaced.
Note
Use this command after the [PRN MAIN REGIST] and [PRN SUB
REGIST] and [CCD MAIN ZOOM] adjustments have been performed.
Adjustment Specification:
Adjust the amount that widths A and B in the copy of the test pattern 1 so that
the following specification is met.
0 ± 2.0 mm
Adjustment Range:
-5.0 (-5.0 mm), ~ 0.0 (0.0 mm default), ~ +5.0 (+5.0 mm)
Step:
0.5 mm
Adjustments and Print Function Settings
6-15