Chery A11 2003 Repair Manual page 783

Table of Contents

Advertisement

Maintenance Manual for Chery · Windcloud
with fuel return interceptor to ensure no fuel
return, and check if fuel pressure is formed
rapidly.
14
Check if leakage or clogging occurs in fuel inlet
pipe
15
Check if fuel return pipe is blocked up or bent.
16
Check if data of intake manifold absolute
pressure and intake air temperature sensor is
normal.
17
Check if spark plug, high voltage line and
ignition coil are in good condition.
18
Check if caused by air conditioning system.
15). Air conditioning system failure
1
Check if there is enough refrigerant in system,
and if air conditioning belt, air conditioning
clutch and pressure switch are working in good
condition.
2
Make engine run at idle speed, and switch on air
conditioning switch. Check with scanner to see
if failure of air-conditioning thermal resistor
occurs.
3
Turn on air conditioning switch, connect
commutator between ECU and wire harness,
and then measure to see if there is signal input
on air conditioning switch, air conditioning
pressure of ECU.
4
In case low-level control is adopted, check if
air-conditionor still works when it is OFF.
5
Check if there is low-level output at ground
terminal of pull-up coil of ECU air conditioning
relay.
M7.9.7 EFI System
No
Repair/
injector or fuel pipe
Yes
Repair or replace fuel
inlet pipe
No
Replace fuel pump
Yes
Repair or replace fuel
return pipe
No
Replace
regulator
Yes
Go to next step
No
Replace sensor
Yes
Go to next step
No
Replace or adjust
Yes
Check
conditioning system
No
Replace ECU
Yes
Go to next step
No
Troubleshooting
Yes
Eliminate
displayed
No
Go to next step
Yes
Go to next step
No
Check wire harness
Yes
Replace
repair wire harness
No
Go to next step
Yes
Repair
conditioning
and wire harness
No
Replace ECU
replace
pressure
air
failure
bulb
or
air
relay
59

Advertisement

Table of Contents
loading

Table of Contents