Chery A11 2003 Repair Manual page 753

Table of Contents

Advertisement

Maintenance Manual for Chery · Windcloud
Check the connection between Pin 2 of carbon
6
canister control valve connector and Pin 46 of ECU
to see if short circuit to ground occurs.
Failure code: P0445 too high driver stage control circuit voltage of carbon
canister control valve
Step
Operation
Connect scanner and commutator, and then turn
1
ignition switch to "ON".
Unplug carbon canister control valve connector
from wire harness, check the voltage between Pin 1
2
of connector and cathode of power supply with a
multimeter to see if it is around 12V.
Check power supply terminal wiring of carbon
3
canister control valve to see if open circuit or short
circuit to ground occurs.
Check the resistance between Pin 1 and Pin 2 of
4
carbon canister control valve with a multimeter to
see if it is between 22-30Ω at 20℃.
Check the voltage between Pin 1 of carbon canister
5
control valve connector and cathode of power
supply with a multimeter to see if it is around 3.7V.
Check the connection between Pin 2 of carbon
6
canister control valve connector and Pin 46 of ECU
to see if short circuit occurs.
Failure code: P0480 control circuit error in relay of Cooling Fan A of air
conditioning condenser
Step
Operation
Connect scanner and commutator, and then turn
1
ignition switch to "OFF".
2
Unplug cooling fan relay of air conditioning
condenser turn ignition switch to ON Check the
M7.9.7 EFI System
Repair
Yes
replace
harness
Diagnosis
No
Instruction
Result
Solution
Go to next step
Yes
Go to Step 4
No
Go to next step
Repair
Yes
replace
harness
No
Go to Step 2
Yes
Go to next step
Replace
No
control valve
Diagnosis
Yes
Instruction
No
Go to next step
Repair
Yes
replace
harness
Diagnosis
No
Instruction
Result
Solution
Go to next step
Yes
Go to Step 4
or
wire
or
wire
or
wire
29