Chery A11 2003 Repair Manual page 283

Table of Contents

Advertisement

Maintenance Manual for Chery·Windcloud
Failure: too high system votage
Step
Operation
Connect scanner and commutator, and then turn
1
ignition switch to "OFF".
Check battery voltage with a multimeter to see if it
2
is around 12V.
Start engine, check charging voltage of generator at
3
different engine speeds to see if it maintains within
9-16V.
Check ground point of engine wire harness to see if
4
it isin good condition.
Failure: non-programmed check code error of ECU
Step
Operation
Connect scanner and commutator, and then turn
1
ignition switch to "ON".
Clear failure code, recheck the failure to see if it is a
2
constant failure.
3
Replace ECU.
Failure: non-programmed diagnostic data identification code error of ECU
Step
Operation
Connect scanner and commutator, and then turn
1
ignition switch to "ON".
Clear failure code, recheck the failure to see if it is a
2
constant failure.
3
Replace ECU.
Failure: control circuit error of air conditioner compressor relay
Step
Operation
Marelli EFI System
Repair
No
replace
harness
Result
Solution
Go to next step
Yes
Go to next step
Replace
No
battery
Yes
Go to next step
Replace
No
generator
Diagnosis
Yes
Instruction
Repair
No
replace
harness
Result
Solution
Go to next step
Yes
Go to next step
No
System normal
Finish
Result
Solution
Go to next step
Yes
Go to next step
No
System normal
Finish
Result
Solution
or
wire
or
wire
32

Advertisement

Table of Contents
loading

Table of Contents