Error Log Menu - Cornelius VIPER 2 FLAVOR Service Manual

Hide thumbs Also See for VIPER 2 FLAVOR:
Table of Contents

Advertisement

Viper Service Manual

Error Log Menu

Publication Number: 621260373SER
Displayed
Action
Message
CO
OUT
2
SYRUP OUT
CLOCK
MTR CTL
EEPROM
Button
BACK
Returns the display to the Select menu
Allows the user to reset the highlighted error (This button only
RESET
appears on certain manually resettable errors.)
The Error Log screen displays information about any errors generated by the unit,
as shown in Figure 18. If no errors have been detected, the right side of the
display is blank. To view more than one error, press the Up or Down arrows on the
right side of the display to scroll through the error log. Button functions are
described in Table 8.
ERROR
LOG
12:51P
MAR 04
BACK
Button
BACK
Returns the display to the Select menu
- 26 -
Table 6
Type
CO
pressure is below required operating
2
pressure. This error occurs when the CO
System
sensor reports no or low CO
more than one second. Error is cleared 10
sec. after restoral.
Syrup pressure is below required operating
pressure. This error occurs when the syrup
Barrel
sensor reports no or low syrup pressure for
more than one second. Error is cleared 10
sec. after restoral.
System
The real time system clock is not functioning.
System
Motor control EEPROM is bad or missing.
Table 7
Description
ERROR NUMBER    2
#3 COMM FAIL
OCCUR:           2:44 PM
3/04/08
CLEAR:             2:52 PM
3/04/08
Figure 18. Error Log Screen
Table 8
Description
Description
2
pressure for
2