3.2.2 Install the Optional Rack Slide Set

CEFD Part Number
FP/SL0007
FP/SL0008
FP/SL0006
If the converter is to be mounted on slides, install the provided bearingless rack slide set into the
rack cabinet, and onto the sides of the LBC-4000/-ST. Use the hardware provided with the slide
set that is determined to be appropriate for installation.
Do these steps to install the slide set (Figure 3-4):
1. Use the provided hardware to install one slide onto each side of the unit chassis.
2. Use the provided hardware to install the slide rail components into each interior side of
the equipment rack cabinet.
3. Install the unit into the front of the equipment rack. Ensure that the slides properly engage
the cabinet-mounted slide rails.
4. Continue to slide the unit into the equipment rack to its final operating position. Then, use
four user-provided screws to secure the unit to the equipment rack's right and left
threaded front rails (through the front panel slots).
Installation and Startup
Bearingless Rack Slide Set – 22"
Bearingless Rack Slide Set – 24"
Bearingless Rack Slide Set – 26"

Figure 3-4. Optional Rack Slide Set Installation

3–6
LBC-4000 L-Band Up/Down Converter System
Description
Revision 6
MN-LBC-4000