Comtech EF Data LBC-4000 Installation And Operation Manual page 120

L-band up/down converter system
Table of Contents

Advertisement

Command
Arguments for
Parameter
(Instruction
Type
Code and
Qualifier)
Concise
N/A
52 bytes,
Configuration
numeric
Status
Serial Interface Operation
Description of Arguments
Command or
(Note that all arguments are ASCII
Response to
numeric codes between 48 and 57)
Query
Query only.
Use "CCS" to return a summarized version of the RCS query.
Returns status info in the form
"CCS_aaaaa.aaabb.bbcd.defffff.fffgg.gghi.ijklmnnnopqqqqrs{cr}{lf}"
where:
aaaaa.aaa=Conv A frequency in MHz
bb.bb=Conv A attenuation in dB
c=Conv A mute state (0=unmuted, 1=muted)
d.d=Conv A slope adjustment level
e=Conv A online/offline (redundancy)
fffff.fff=Conv B frequency in MHz
gg.gg=Conv B attenuation in dB
h=Conv B mute state (0=unmuted, 1=muted)
i.i=Conv B slope adjustment level
j=Conv B online/offline (redundancy)
k=Converter redundancy mode
l=auto fault recovery (1=auto, 0=manual)
m=External Ref present (0=none, 1=present)
nnn=Internal Ref Osc adjustment level (000-255)
o=remote mode (1=remote, 0=local)
p=remote interface (0=EIA-232, 1=EIA-485)
qqqq=remote address (0001-9999)
r=remote baud rate (0=38400, 1=19200, 2=9600, 3=4800,
4=2400, 5=1200)
s=remote data format (0=8N1, 1=7E2, 2=7O2)
LBC-4000 L-Band Up/Down Converter System
8–10
Revision 6
Response to
Query
Response to
Command
(Instruction
Query
(Target to
Code and
(Target to
Controller)
Qualifier)
Controller)
N/A
CCS_a...s
CCS_
MN-LBC-4000

Advertisement

Table of Contents
loading

Table of Contents