Command
Arguments for
Parameter
(Instruction
Type
Code and
Qualifier)
Set
SAM_
1 byte,
Auto/Manual
alphabetic
Switching Mode
Summary Alarm
N/A
2 bytes,
Status
alphabetic
Remote Baud
SBR_
4 bytes,
Rate
alphanumeric
Set Physical
SPA_
4 bytes,
Address
numeric
Serial Interface Operation
Description of Arguments
Command or
(Note that all arguments are ASCII
Response to
numeric codes between 48 and 57)
Query
Command or Query.
Use "SAM" to set or return the operating redundancy switching
mode as Automatic or Manual.
Set or return in the form SAM_x where:
x=A (Automatic Switching Mode)
x=M (Manual Switching Mode)
Command Example: <0001/SAM_M{cr}
Query only.
Use "SAS" to return the status of the Summary Fault Relay.
Returns Summary Fault Relay status in the form SAS_xx where:
xx=OK
xx=FT
Command or Query.
Use "SBR" to set or return the serial baud rate of the unit.
Set or return in the form SBR_xxxx where:
xxxx=remote baud rate where:
1200=1200 baud
2400=2400 baud
4800=4800 baud
9600=9600 baud
19K2=19200 baud
38K4=38400 baud
Command Example:
<0001/SBR_38K4{cr} (sets baud rate to 38400 baud)
Command or Query.
Use "SPA" to set or return the physical remote device address for
the unit.
Set or return in the form SPA_xxxx where:
xxxx=Physical Address from 0001 to 9999 (Resolution=0001)
Command Example:
<0001/SPA_0412{cr} (sets physical device address to 0412)
LBC-4000 L-Band Up/Down Converter System
8–21
Revision 6
Response to
Query
Response to
Command
(Instruction
Query
(Target to
Code and
(Target to
Controller)
Qualifier)
Controller)
SAM_
SAM_x
SAM_
N/A
SAS_x
SAS_
SBR_
SBR_xxxx
SBR_
SPA_
SPA_xxxx
SPA_
MN-LBC-4000

Advertisement