Comtech EF Data LBC-4000 Installation And Operation Manual page 125

L-band up/down converter system
Table of Contents

Advertisement

Command
Arguments for
Parameter
(Instruction
Type
Code and
Qualifier)
List All Alarms
N/A
Varies
Local or
LRS_
1 byte, numeric,
Remote State
0 to 3
Retrieve Unit
N/A
12 bytes,
MAC Address
alphanumeric
Serial Interface Operation
Description of Arguments
Command or
(Note that all arguments are ASCII
Response to
numeric codes between 48 and 57)
Query
Query only.
Use "LAA" to return the list of stored alarms.
Return stored alarms in the form:
"xx yyyyyyyyyyy hh:mm:ss mm/dd/yy{cr}
"
"
"
"
xx yyyyyyyyyyy hh:mm:ss mm/dd/yy{cr}{lf}"
where:
xx=stored fault number
yyyyyyyyyyy=fault description
hh:mm:ss=fault time
mm/dd/yy=fault date
Command or Query.
Use "LRS" to set or return the unit operating mode.
Set or return in the form LRS_x where:
x= 0 (Local)
x=1 (Serial Remote EIA-232/485)
x=2 (Ethernet Remote)
x=3 (Ethernet+Serial Remote)
Query only.
Returns the factory-assigned MAC address for the unit, in
hexadecimal.
Return in the form LRS_x where:
x= 0 (Local)
x=1 (Serial Remote EIA-232/485)
x=2 (Ethernet Remote)
x=3 (Ethernet+Serial Remote)
Query Response Example: >0001/MAC_0006B00001C2{cr}{lf}
"
"
{cr}
"
"
{cr}
8–15
LBC-4000 L-Band Up/Down Converter System
Response to
Query
Response to
Command
(Instruction
(Target to
Code and
(Target to
Controller)
Qualifier)
Controller)
N/A
LAA_
LAA_ xx y...y
h...s m...y
LRS_
LRS_x
LRS_
N/A
MAC_aabbccd
MAC_
deeff
MN-LBC-4000
Revision 6
Query

Advertisement

Table of Contents
loading

Table of Contents