Comtech EF Data LBC-4000 Installation And Operation Manual page 130

L-band up/down converter system
Table of Contents

Advertisement

Command
Arguments for
Parameter
(Instruction
Type
Code and
Qualifier)
Retrieve
N/A
203 bytes,
Maintenance
alphanumeric
Status
Retrieve Utility
N/A
98 bytes,
Status
alphanumeric
Serial Interface Operation
Description of Arguments
Command or
(Note that all arguments are ASCII
Response to
numeric codes between 48 and 57)
Query
Query only.
Use "RMS" to return the maintenance status of the unit.
Returns detailed maintenance status for the unit:
12VT1=xxx.x{cr}
08VT1=xxx.x{cr}
05VT1=xxx.x{cr}
12VT2=xxx.x{cr}
08VT2=xxx.x{cr}
05VT2=xxx.x{cr}
VTREF=xxx.x{cr}
IFLOA=xxx.x{cr}
RFLOA=xxx.x{cr}
PIN_A=xxx.x{cr}
POUTA=xxx.x{cr}
TEMPA=xxx.x{cr}
IFLOB=xxx.x{cr}
RFLOB=xxx.x{cr}
PIN_B=xxx.x{cr}
POUTB=xxx.x{cr}
TEMPB=xxx.x{cr}
Legacy Query only.
Use "RUS" to return the operating utility features for the unit.
Return the detailed utility status for the unit where:
hh:mm:ss=TIME
mm/dd/yy=DATE
xxxx=FSDA (Reserved for future use)
xxxx=FSDB (Reserved for future use)
yyy=BVFD
zzz=SCRT
FW9965X=BULK FW (where X=revision letter)
FW9966X=M&C FW (where X=revision letter)
FW9967X=FPGA FW (where X=revision letter)
12VDC Supply #1 in volts
8VDC Supply #1 in volts
5VDC Supply #1 in volts
12VDC Supply #2 in volts
8VDC Supply #2 in volts
5VDC Supply #2 in volts
Ref Osc tuning in volts
Conv A IFLO tuning in volts
Conv A RFLO tuning in volts
Conv A Input power in dBm
Conv A Output power in dBm
Conv A temperature in deg C
Conv B IFLO turning in volts
Conv B RFLO tuning in volts
Conv B Input power in dBm
Conv B Output power in dBm
Conv B temperature in deg C
8–20
LBC-4000 L-Band Up/Down Converter System
Response to
Query
Response to
Command
(Instruction
(Target to
Code and
(Target to
Controller)
Qualifier)
Controller)
N/A
RMS_x...x
RMS_
N/A
RUS_x...x
RUS_