Command
Arguments for
Parameter
(Instruction
Type
Code and
Qualifier)
Attenuation
ATT_y_xx.xx
7 bytes,
Level
alphanumeric
Clear All Alarms
CAA_xxx{cr}
3 bytes,
alphabetic
Concise Alarm
N/A
13 bytes,
Status
numeric
Serial Interface Operation
Description of Arguments
Command or
(Note that all arguments are ASCII
Response to
numeric codes between 48 and 57)
Query
Command or Query.
Use "ATT" to set or return the attenuation level, in dB, in 0.1 dB
steps.
Set or return in the form ATT_y_xx.xx where:
y=A (Conv A) or B (Conv B)
xx.xx=Valid attenuation level, in dB (0.1 dB step size is factory
default)
Command Example: <0001/ATT_A_+12.20{cr}
Command only.
Use "CAA" to clear all stored alarms from the Target's events log.
Set or return in the form CAA_xxx where:
xxx=YES
Command Example: <0001/CAA_YES{cr}
Query only.
Use "CAS" to return the Alarm Status for the unit.
Returns alarm status as 0 = NO FAULT or 1 = FAULT for each item
in the form "CAS_abcdefghijklm{cr}{lf}" where:
a=12VDC #1 Fault
b=8VDC #1 Fault
c=5VDC #1 Fault
d=12VDC #2 Fault
e=8VDC #2 Fault
f=5VDC #2 Fault
g=REF LD Fault
h=IFLO A Fault
i=RFLO A Fault
j=TEMP A Fault
k=IFLO B Fault
l=RFLO B Fault
m=TEMP B Fault
LBC-4000 L-Band Up/Down Converter System
8–9
Revision 6
Response to
Query
Response to
Command
(Instruction
Query
(Target to
Code and
(Target to
Controller)
Qualifier)
Controller)
ATT_y_xx.xx
ATT_y_ xx.xx
ATT_y_
CAA_CLEAR
N/A
N/A
ED
N/A
CAS_x...x
CAS_
MN-LBC-4000