Comtech EF Data LBC-4000 Installation And Operation Manual page 123

L-band up/down converter system
Table of Contents

Advertisement

Command
Arguments for
Parameter
(Instruction
Type
Code and
Qualifier)
Fault Relay
FRL_
1 byte, numeric
Logic
Retrieve
N/A
0 bytes
Firmware
Number
Retrieve
N/A
0 bytes
Legacy
Firmware
Number
Serial Interface Operation
Description of Arguments
Command or
(Note that all arguments are ASCII
Response to
numeric codes between 48 and 57)
Query
Command or Query.
Use "FRL" to set or return the fault relay logic.
Set or return info in the form FRL_x where:
x=0 (Normal Logic)
x=1 (Inverted Logic)
Query only.
For use with current (Ethernet-ready) versions of the LBC-4000/-ST.
Returns the firmware information for the unit.
Returns the current unit firmware info in the form:
"Boot: {cr}
FW-0020506;X.X.X;mm/dd/yy{cr}
Bulk1: {cr}
FW-0020503; X.X.X;mm/dd/yy{cr}
FW-0020504; X.X.X;mm/dd/yy{cr}
FW-0020505; X.X.X;mm/dd/yy{cr}
Bulk2: {cr}
FW-0020503; X.X.X;mm/dd/yy{cr}
FW-0020504; X.X.X;mm/dd/yy{cr}
FW-0020505; X.X.X;mm/dd/yy{cr}{lf}"
where:
X.X.X is the Firmware Version Number, and
mm/dd/yy is the release date.
Query only.
For use with legacy (non-Ethernet) versions of the LBC-4000.
Returns the firmware information for the unit.
Returns the legacy unit firmware info in the form:
"BULK=FW/9965X{cr}
M&C=FW/9966X{cr}
FPGA=FW/9967X{cr}{lf}"
where:
'X' denotes the Firmware Revision Letter)
LBC-4000 L-Band Up/Down Converter System
8–13
Revision 6
Response to
Query
Response to
Command
(Instruction
Query
(Target to
Code and
(Target to
Controller)
Qualifier)
Controller)
FRL_
FRL_
FRL_x
N/A
FRM_x...x
FRM_
N/A
FRW_x
FRW_
MN-LBC-4000