Advertisement

Command
Arguments for
Parameter
(Instruction
Type
Code and
Qualifier)
Retrieve Alarm
N/A
122 bytes,
Status
alphanumeric
Serial Interface Operation
Description of Arguments
Command or
(Note that all arguments are ASCII
Response to
numeric codes between 48 and 57)
Query
Query only.
Use "RAS" to return the alarm status for the unit.
Return the detailed alarm status, where
xx=OK (NO FAULT)
12VDC1_xx{cr}
08VDC1_xx{cr}
05VDC1_xx{cr}
12VDC2_xx{cr}
08VDC2_xx{cr}
05VDC2_xx{cr}
REFLD_xx{cr}
IFLOA_xx{cr}
RFLOA_xx{cr}
TEMPA_xx{cr}
IFLOB_xx{cr}
RFLOB_xx{cr}
TEMPB_xx{cr}{lf}
xx=FT (FAULT):
12VDC #1 Fault
8VDC #1 Fault
5VDC #1 Fault
12VDC #2 Fault
8VDC #2 Fault
5VDC #2 Fault
Ref Osc Lock Detect Fault*
Conv A IFLO Lock Detect Fault
Conv A RFLO Lock Detect Fault
Conv A Over Temperature Fault
Conv B IFLO Lock Detect Fault
Conv B RFLO Lock Detect Fault
Conv B Over Temperature Fault
*Note: "REFLD" is returned only when an external reference is
present
LBC-4000 L-Band Up/Down Converter System
8–17
Revision 6
Response to
Query
Response to
Command
(Instruction
Query
(Target to
Code and
(Target to
Controller)
Qualifier)
Controller)
N/A
RAS_x...x
RAS_
MN-LBC-4000

Advertisement