Comtech EF Data LBC-4000 Installation And Operation Manual page 128

L-band up/down converter system
Table of Contents

Advertisement

Command
Arguments for
Parameter
(Instruction
Type
Code and
Qualifier)
Retrieve
N/A
186 bytes,
Configuration
alphanumeric
Status
Redundancy
RED_
3 bytes,
Mode
alphabetic
Serial Interface Operation
Description of Arguments
Command or
(Note that all arguments are ASCII
Response to
numeric codes between 48 and 57)
Query
Query only.
Use "RCS" to return the configuration status for the unit.
Return the detailed configuration status for the unit:
FRE_A_xxxxx.xxx
ATT_A_xx.xx
TX_A_yyy
SLP_A_x.x
ONL_A_yyy
FRE_B_xxxxx.xxx
ATT_B_xx.xx
TX_B_yyy
SLP_B_x.x
ONL_B_yyy
RED_yyy
AFR_yyy
EXT_yyy
REF_xxx
REM_yyy
COMM_RS-xxx
ADD_xxxx
BR_xxxx
FMT_X-X-X
Command or Query.
Use "RED" to set or return the active redundancy mode.
Set or return in the form RED_yyy where:
yyy=ON (Redundancy is enabled)
yyy=OFF (Redundancy is disabled)
Conv A frequency
Conv A attenuation
Conv A mute state
Conv A slope adjustment
Conv A ONline/OFFline
Conv B frequency
Conv B attenuation
Conv B mute state
Conv B slope adjustment
Conv B ONline/OFFline
Conv Redundancy ON/OFF
Auto Fault Recovery ON/OFF
External Reference YES/NO
Ref Osc Adjustment
Remote Mode YES/NO
Remote Interface RS-232/RS-485
Remote Address 0001-9999
Remote Baud Rate
Remote Data Format
8–18
LBC-4000 L-Band Up/Down Converter System
Response to
Query
Response to
Command
(Instruction
(Target to
Code and
(Target to
Controller)
Qualifier)
Controller)
N/A
RCS_F...X
RCS_
RED_
RED_
RED_
MN-LBC-4000
Revision 6
Query

Advertisement

Table of Contents
loading

Table of Contents