Compaq ProLiant 800 Manual page 37

Hide thumbs Also See for ProLiant 800:
Table of Contents

Advertisement

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-8
Server Management
Critical Error Log Messages
Processor Prefailure
FS_CPU_Prefailure_Cache
NMI - PCI Bus Parity Error
NMI - Expansion Board Error
NMI - Expansion Bus Master
Time-Out
NMI - Expansion Bus Slave Time-
Out
NMI - Fail-Safe Timer Expiration
Processor Exception
NMI - Processor Parity Error
Server Manager Failure
NMI - Software Generated
Interrupt Detected Error
Caution: Temperature Exceeded
continued
Message
A CPU has passed an internal corrected error
threshold - Excessive internal ECC cache errors.
A parity error was detected on the PCI bus.
A board on the expansion bus indicated an error
condition, resulting in a server failure.
A bus master expansion board in the indicated slot
did not release the bus after its maximum time,
resulting in a server failure.
A board on the expansion bus delayed a bus
cycle beyond the maximum time, resulting in a server
failure.
Software was unable to reset the system fail-safe
timer, resulting in a server failure.
The indicated processor exception occurred.
The processor detected a data error, resulting in a
server failure.
An error occurred with the Server Manager/R.
Software indicated a system error, resulting in a
server failure.
The operating system has detected that the
temperature of the system has exceeded the caution
level. Accompanying data in the log notes if an auto-
shutdown sequence has been invoked by the
operating system.
Writer: Project: Server Management Comments:
File Name: D-ch2.doc Last Saved On: 4/23/97 11:14 AM
Description