Compaq ProLiant 800 Manual page 145

Hide thumbs Also See for ProLiant 800:
Table of Contents

Advertisement

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
POST Error Messages
Error Code
1784-Drive Array
Drive Failure, Physical
Drive
1785-Drive Array not
Configured
1786-Drive Array
Recovery Needed
The following drive(s)
need Automatic Data
Recovery: Drive X.
Select "F1" to
continue with
recovery of data to
drive(s).
Select "F2" to
continue without
recovery of data to
drive(s).
1787-Drive Array
Operating in Interim
Recovery Mode.
Physical drive
replacement needed:
Drive X
continued
Audible
Beeps
L=Long
S=Short
None
Defective drive and/or
cables
None
Configuration error
None
Interim Data Recovery
mode. Data has not been
recovered yet.
None
Hard drive X failed or
cable is loose or defective.
After system restart,
message reminds you that
drive X is defective and
fault tolerance is being
used.
Writer: Project: Diagnostics Tools Comments:
File Name: J-ch8.doc Last Saved On: 4/24/97 10:38 AM
Probable Source of
Problem
Check for loose
cables. Replace
defective drive X
and/or cables(s)..
Run the System
Configuration Utility
and correct.
Press F1 key to allow
Automatic Data
Recovery to begin.
Data will automatically
be restored to drive X
now that the drive has
been replaced or now
seems to be working.
-Or-
Press the F2 key and
the system will
continue to operate in
the Interim Data
Recovery mode.
1. Replace drive X as
soon as possible.
2. Check loose
cables.
3. Replace defective
cables.
Compaq ProLiant 800 Server Reference Guide
8-15
Action
continued

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents