8-46
Diagnostics Tools
DAAD Diagnostic Messages
Message
Insufficient adapter
resources
Less than 75% batteries
at sufficient voltage
Logical drive X failed due
to cache error
continued
Description
The adapter does not have
sufficient resources to
perform operations to the
array accelerator board.
Drive rebuild may be
occurring.
The operation of the array
accelerator board has
been disabled due to less
than 75% of the battery
packs being at the
sufficient voltage level.
This logical drive failed
due to a catastrophic
cache error.
Writer: Project: Diagnostics Tools Comments:
File Name: J-ch8.doc Last Saved On: 4/24/97 10:38 AM
Recommended Action
Operate the system without the array
accelerator board until the drive rebuild
completes.
Allow sufficient time for the batteries to
recharge (36 hours). If the batteries have not
recharged after 36 hours, replace the array
accelerator board.
Replace the array accelerator board and
reconfigure using the System Configuration
Utility.
continued