8-40
Diagnostics Tools
DAAD Diagnostic Messages
Message
Configuration signature
mismatch
Controller
communication failure
occurred
Controller detected.
NVRAM configuration not
present
Controller firmware
needs upgrading
Controller firmware
needs upgrading (DAAD
Error 102)
continued
Description
Array accelerator board
configured for a different
array controller board.
Configuration signature on
array accelerator board
does not match the one
stored on the array
controller board.
Controller communication
failure occurred.
EISA nonvolatile RAM does
not contain a configuration
for this controller.
Controller firmware is
below the latest
recommended version.
Controller is correct,
however, IDA firmware
version should be greater
than 1.26.
Writer: Project: Diagnostics Tools Comments:
File Name: J-ch8.doc Last Saved On: 4/24/97 10:38 AM
Recommended Action
To recognize the array accelerator board, run
the System Configuration Utility.
DAAD was unable to successfully issue
commands to the controller in this slot.
Run the System Configuration Utility to
configure the nonvolatile RAM.
Run Options ROMPaq to upgrade the controller
to the latest firmware revision.
Call your Authorized Compaq Reseller to obtain
the latest firmware.
continued