Compaq ProLiant 800 Manual page 147

Hide thumbs Also See for ProLiant 800:
Table of Contents

Advertisement

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
POST Error Messages
Error Code
1789-Drive Not
Responding, Physical
Drive
Check cables or
replace physical drive
X.
Select F1 to continue
- drive array will
remain disabled.
Select F2 to fail
drive(s) that are not
responding -
Interim Recovery
Mode will be enabled
if configured for fault
tolerance.
1790-Disk 0 Error
1790-Disk 0
Configuration Error
1791-Disk 1 Error
continued
Audible
Beeps
L=Long
S=Short
None
Cable or hard drive
failure.
None
Hard drive error or wrong
drive type
None
Hard drive error or wrong
drive type
None
Hard drive error or wrong
drive type.
Writer: Project: Diagnostics Tools Comments:
File Name: J-ch8.doc Last Saved On: 4/24/97 10:38 AM
Probable Source of
Problem
1. Check the cable
connections.
2. If cables are
connected, replace
the drive.
3. If you do not want
to replace the
drives now, press
F2.
Run the System
Configuration Utility.
Run the System
Configuration Utility
and Diagnostics.
Run the System
Configuration Utility
and Diagnostics and
correct.
Compaq ProLiant 800 Server Reference Guide
8-17