DAAD Diagnostic Messages
Message
Accelerator parity write
errors: n
Accelerator status:
Permanently disabled
Accelerator status:
Possible data loss in
cache
Accelerator status:
Temporarily disabled
Accelerator status:
Unrecognized status
continued
Description
Number of times that write
memory parity errors were
detected during transfers to
memory on the array
accelerator board.
Array accelerator board has
been permanently disabled.
It will remain disabled until
it is reinitialized using the
System Configuration Utility.
Possible data loss detected
during power-up due to all
batteries being below
sufficient voltage level and
no presence of the
identification signatures on
the array accelerator board.
Array accelerator board has
been temporarily disabled.
A status returned from the
array accelerator board that
DAAD does not recognize.
Writer: Project: Diagnostics Tools Comments:
File Name: J-ch8.doc Last Saved On: 4/24/97 10:38 AM
Recommended Action
If there are many parity errors, you may need
to replace the array accelerator board.
Check the Disable Code field. Run the System
Configuration Utility to reinitialize the array
accelerator board.
There is no way to determine if dirty or bad
data was in the cache and is now lost.
Check the Disable Code field.
Call your Authorized Compaq Reseller for the
latest copy of DAAD.
Compaq ProLiant 800 Server Reference Guide