POST Error Messages
Error Code
1771-Primary Disk
Port Address
Assignment Conflict
1772-Secondary Disk
Port Address
Assignment Conflict
1773-Primary Fixed
Disk Port Assignment
Conflict
1774- Slot x Drive
Array - Obsolete data
found in Array
Accelerator.
Select F1 to discard
contents of Array
Accelerator.
Select F2 to write
contents of Array
Accelerator to drives.
1776-Drive Array -
SCSI Port Termination
Error
continued
Audible
Beeps
L=Long
S=Short
None
Internal and external hard
drive controllers are both
assigned to the primary
address.
None
Address Assignment
Conflict. Internal and
external hard drive
controllers are both
assigned to the
secondary address.
None
Fixed disk drive error.
None
SMART-2 Controller error
None
External and internal SCSI
drives are both configured
to Port 1.
Writer: Project: Diagnostics Tools Comments:
File Name: J-ch8.doc Last Saved On: 4/24/97 10:38 AM
Probable Source of
Problem
Run the System
Configuration Utility
and correct.
Run the System
Configuration Utility
and correct.
Run the System
Configuration Utility
and correct.
Data found in Array
Accelerator is older
than data found on
drives. Press F1 to
discard the older data
in the Array
Accelerator and retain
the newer data on the
drives.
Reconfigure drives.