POST Error Messages
Error Code
1702-SCSI cable error
detected
System halted.
1703-SCSI cable error
detected. Internal
SCSI cable not
attached to system
board connector.
System halted.
1704-Unsupported
Virtual Mode Disk
Operation. DOS Driver
Required. System
Halted.
1705-Locked SCSI
Bus Detected. System
Halted.
1730-Fixed Disk 0
does not support
DMA Mode
continued
Audible
Beeps
L=Long
S=Short
None
Incorrect cabling
None
Incorrect cabling
None
System attempted to
perform a virtual mode
disk operation without
virtual mode memory
services.
None
SCSI bus failure
None
Fixed disk drive error
Writer: Project: Diagnostics Tools Comments:
File Name: J-ch8.doc Last Saved On: 4/24/97 10:38 AM
Probable Source of
Problem
1. For Integrated SCSI
Controllers, ensure
that the internal
connector has SCSI
termination
attached.
2. For option card SCSI
controllers, ensure
that only one of the
two internal
connectors has
termination
attached.
Ensure that the
integrated SCSI
controller has SCSI
termination attached.
Use fixed-disk device
driver that supports
virtual mode memory
services.
Run Diagnostics.
Contact your service
provider.
Run the System
Configuration Utility
and correct.