8-18
Diagnostics Tools
POST Error Messages
Error Code
1792-Drive Array
Reports Valid Data
Found in Array
Accelerator.
Data will
automatically be
written to drive array.
1793-Drive Array -
Array Accelerator
Battery Depleted -
Data Lost
(Error message 1794
also displays.)
1794-Drive Array -
Array Accelerator
Battery Charge Low.
Array Accelerator is
temporarily disabled.
Array Accelerator will
be reenabled when
battery reaches full
charge.
continued
Audible
Beeps
L=Long
S=Short
None
While the system was in
use, power was
interrupted while data
was in the Array
Accelerator memory.
Power was then restored
within eight to ten days,
and the data in the Array
Accelerator was flushed to
the drive array.
None
This indicates that while
the system was in use,
power was interrupted
while data was in the
Array Accelerator memory.
Array Accelerator batteries
failed. Data in Array
Accelerator has been lost.
None
This is a warning that the
battery charge is below
75%. Posted writes are
disabled.
Writer: Project: Diagnostics Tools Comments:
File Name: J-ch8.doc Last Saved On: 4/24/97 10:38 AM
Probable Source of
Problem
No action necessary;
no data has been lost.
Perform orderly
system shut-downs to
avoid data remaining
in the Array
Accelerator.
Power was not
restored within eight
to ten days. Perform
orderly system shut-
downs to avoid data
remaining in the Array
Accelerator.
Replace the Array
Accelerator board if
batteries do not
recharge within 36
power-on hours.
Action
continued