Compaq ProLiant 800 Manual page 168

Hide thumbs Also See for ProLiant 800:
Table of Contents

Advertisement

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-38
Diagnostics Tools
DAAD Diagnostic Messages
Message
Accelerator status: Valid
data found at reset
Accelerator status:
Warranty alert
Adapter/NVRAM ID
mismatch
Battery pack X below
reference voltage
Battery X not fully
charged
continued
Description
Valid data was found in
posted write memory at
reinitialization. Data will be
flushed to disk.
Catastrophic problem with
array accelerator board.
Refer to other messages on
Diagnostics screen for exact
meaning of this message.
EISA nonvolatile RAM has
an ID for a different
controller from the one
physically present in the
slot.
Battery pack on the array
accelerator is below the
required voltage levels.
Battery is not fully
charged.
Writer: Project: Diagnostics Tools Comments:
File Name: J-ch8.doc Last Saved On: 4/24/97 10:38 AM
Recommended Action
Not an error or data loss condition. No action
needs to be taken.
Replace the array accelerator board.
Run the System Configuration Utility.
Allow enough time for batteries to recharge (36
hours). If batteries have not recharged after 36
hours, replace the array accelerator board.
If 75% of the batteries present are fully
charged, the array accelerator is fully
operational. If more than 75% of the batteries
are not fully charged, allow 36 hours to
recharge them.
continued