Compaq ProLiant 800 Manual page 178

Hide thumbs Also See for ProLiant 800:
Table of Contents

Advertisement

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-48
Diagnostics Tools
DAAD Diagnostic Messages
Message
Logical Drive X status =
NEEDS RECOVER
Logical Drive X status =
OVERHEATED
Logical Drive X status =
OVERHEATING
Logical Drive X status =
RECOVERING
Logical Drive X status =
WRONG DRIVE
REPLACED
continued
Description
A physical drive in this
logical drive has failed and
has now been replaced.
This drive needs to be
rebuilt from the mirror
drive or the parity data.
The temperature of the
Intelligent Array Expansion
System drives is beyond
safe operating levels and it
has shut down to avoid
damage.
The temperature of the
Intelligent Array Expansion
System drives is beyond
safe operating levels.
A physical drive in this
logical drive has failed and
has now been replaced.
The replaced drive is
rebuilding from the mirror
drive or the parity data.
A physical drive in this
logical drive has failed.
The incorrect drive was
replaced.
Writer: Project: Diagnostics Tools Comments:
File Name: J-ch8.doc Last Saved On: 4/24/97 10:38 AM
Recommended Action
When booting up the system, select the "F1 -
rebuild drive" option to rebuild the replaced
drive.
Check the fans and the operating environment.
Check the fans and the operating environment.
Nothing needs to be done. Normal operations
can occur.
Replace the drive that was incorrectly replaced.
Then, replace the original drive that failed with
a new drive. Do not run the System
Configuration Utility to reconfigure - you will
lose data on the drive.
continued

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents