Sensor Cables; Connectors Of The P-Sensors And The Sensor Cable - Roland R1000 Series Manual

Double sheet detector
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

Technical data
2.5

Sensor cables

Suitable cable types:
Oilflex FD810CY 2 x 1mm
Unitronic FDCP (TP) plus 1 x 2 x 1mm
ROLAND ELECTRONIC uses according to standard the Oilflex FD810CY 2 x 1mm
Both cables are oil-proof and suitable for drag chains
- Bending radius fix use 31 mm
- Bending radius flexible use 58 mm
Cable marking:
for P30GS and P42AGS
- SM12CPM12S-GG
- SM12CPM12S-GW
for P36GS / P42GS / P75GS / P75VGS
- SM12CPS-GG
- SM12CPS-GW
for P128GPPS
- SM12CPPPS-GG
- SM12CPPPS-GW
The cables are equipped with quick disconnect plug at the sensor side and with bootlace ferrules at
the control unit side.
2.6

Connectors of the P-sensors and the sensor cable

For the connection of the P-sensors can be used as in the following picture.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
22
Double Sheet Detector R1000 series E20
with integrated fieldbus interface
²
(straight receptacle at the sensor)
(right angle receptacle at the sensor)
(straight receptacle at the sensor)
(right angle receptacle at the sensor)
(straight receptacle at the sensor)
(right angle receptacle at the sensor)
Note
The sensor cable is an active component of the sensor technology. The
technical data of the sensors is valid only if the cable specification is met. A
shielded 2 x 1 mm² cable must be used. The cable length can be to up to
50 m. Following the rule "the shorter the better" generally leads to better
measuring results.
Note
The sensor cable is an active part of the sensor. The performance data is
therefore based on the compliance with cable specification.
Manual
²
(UL / CSA)
B0046191 / Rev. 1.12
2
cable.

Advertisement

Table of Contents
loading

This manual is also suitable for:

E20

Table of Contents