Roland R1000 Series Manual page 57

Double sheet detector
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

B0046191 / Rev. 1.12
4.3.7
Clamping bracket SHK
The clamping bracket SHK can be used for the mounting of the spring loaded sensor brackets
SHS...GS or SH...GS.
All Dimensions are in mm. Tolerance:
Fig. 33: Clamping bracket SHK
4.3.8
Electromagnetic interference
Electromagnetic interference can affect the measuring accuracy of the sensor. Therefore the
sensors should not be installed close to devices which cause electromagnetic interference. Such
devices are e.g. frequency converters, servo motors or proximity switches on inductive basis. In
case of switching magnets a minimum distance of 20 mm should be observed in order to avoid
feedback.
The sensor cables should not be placed directly adjacent to cables with large interference potential,
e.g. power supply cable. This applies especially to longer cable lengths.
Pos: 38 /Doppelblech/Geräte/E20 Bus/4 Montage/Fehlerhafter Einbau der P-Sensoren @ 0\mod_1173692370656_501.docx @ 3394 @ 3 @ 1
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series E20
with integrated fieldbus interface
94
25
.
.
M20
± 0.2 mm.
Manual
M8
Mounting
57

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E20

Table of Contents