Start-up
System parameter 8: Switching the password function on / off.
system parameter
password:
Fig. 84: Switching the password on / off
System parameter 9: Selecting the speed of measurement.
system parameter
measurement:
Fig. 85: Selecting the speed of measurement
Possible choices:
normal:
fast:
System parameter 10: Specifying the type of sensor.
system parameter
sensor type: P42
Fig. 86: Specifying the type of sensor
Possible choices:
P30
P36
P42
P42A
P75
P75V
P128
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
118
Double Sheet Detector R1000 series E20
with integrated fieldbus interface
8
yes
Attention
If no password is activated, then all parameters can be accessed at
any time. We recommend this only during starting-up the system. For
daily operation the password function should be activated.
9
fast
Here the system reaction time depends on the measured sheet thickness.
The maximum can be inferred from the diagrams in chapter "2.4 Sensor
data.
Here the system is enabled to detect double sheets before the "normal" end
of the measurement. The system reaction time is shorter and depending on
the adjusted nominal thickness as well as the upper limit value.
Disadvantage: In case of measuring results larger than the double sheet
threshold, a double sheet signal is issued but not the actual measurement
values.
10
Attention
Changing the current configuration will delete all stored program
parameters. Then for all sheet types the nominal thickness values
must be re-entered and the Teach-In must be performed again.