Mounting; General Mounting Instructions - Roland R1000 Series Manual

Double sheet detector
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

B0046191 / Rev. 1.12
4

Mounting

Pos: 28 /Doppelblech/Geräte/E20 Bus/4 Montage/Montage - Allgemeine Hinweise @ 0\mod_1173695080093_501.docx @ 3424 @ 2 @ 1
The mounting of the Double Sheet Detector R1000 E20 determines the measurement accuracy
and the reliability of operation.
The system was designed for operating in rough industrial environments. However, the following
mounting instructions should be observed in order to minimize mechanical, thermal, and
electromagnetic influences on the operation.
4.1

General mounting instructions

The enclosure for wall mounting meets IP65 and is designed for mounting the enclosure close to
the sensor location. This results in the use of shorter sensor cables with a corresponding lower
exposure to electromagnetic noise and could therefore result in better measurements.
The control unit should be installed in locations where no vibration exists and no additional heat is
transferred into the system (even better reduce the heat in the control unit). In addition the control
unit should be installed in such a fashion that it can be easily opened for service purposes. During
the operation the control unit and the sensors should be under visual control of the operating
personnel.
In case of panel or operator consoles the front panel version should be used.
Pos: 29 /Doppelblech/Geräte/E20 Bus/4 Montage/Abmessungen des Gerätes @ 0\mod_1173694060953_501.docx @ 3419 @ 233 @ 1
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series E20
with integrated fieldbus interface
Attention
Strong vibrations and additional heat can damage the control unit.
Manual
Mounting
39

Advertisement

Table of Contents
loading

This manual is also suitable for:

E20

Table of Contents