Roland R1000 Series Manual page 103

Double sheet detector
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

B0046191 / Rev. 1.12
6.6.4
EDS file for CanOpen
The EDS file contains the specific configuration data of the slaves. The data must be known to the
master.
The manufacturers of the master supply the tools for the integration of the EDS file into the
network. Roland Electronic does not supply such tools, because they have to be compatible with
the interface design of the master.
The EDS file is supplied on a CD or can be downloaded from the Roland homepage.
6.6.5
GSD file for ProfiNet IO
The GSD file contains the specific configuration data of the device. The data must be known to the
controller.
The manufacturers of the controller supply the tools for the integration of the GSD file into the
Profibus network. Roland Electronic does not supply such tools, because they have to be
compatible with the interface design of the controller.
The GSD file is supplied on a CD or can be downloaded from the Roland homepage.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series E20
with integrated fieldbus interface
Note
3 PDOs with 8 Bytes each are set.
Note
24 Bytes I/O must be set.
Manual
Communication with the PLC
103

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E20

Table of Contents