Cable Allocation Of S/E-Sensors And Sensor Cables Kiss And Kise - Roland Double Sheet Detector I100 Manual

For double sided sensors
Table of Contents

Advertisement

B0003308 / 1.4 /
13.02.2013
2.3.2

Cable allocation of S/E-sensors and sensor cables KISS and KISE

For sensors and cables before February 2008
S...
Transmitter
E...
Receiver
S...S
Transmitter
E...S
Receiver
Fig. 6: Cable allocation of S/E sensors and sensor cables before february 2008
Sensoren_deu.wmf
For sensors and cables after February 2008
S...
Transmitter
E...
Receiver
S...S
Transmitter
E...S
Receiver
Fig. 7: Cable allocation of S/E sensors and sensor cables after February 2008
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R100 I100
S/E sensors with black cables should no longer be used.
Note:
Manual
for pairs of sensors
1×2×0,25mm (pair-wise twisted)
2
1×2×0,25mm (pair-wise twisted)
2
KISS
1×2×0,25mm (pair-wise twisted)
2
KISE
1×2×0,25mm (pair-wise twisted)
2
3×0,25mm
2×0,25mm
KISS
3×0,25mm
KISE
2×0,25mm
Technical data
brown
white
blank (shield)
brown
white
blank (shield)
blank (shield) [3]
white [2]
brown [1]
white [3]
blank (shield)
brown [1]
Kabelbelegung_SE-
brown
white
green
2
blank (shield)
brown
white
2
blank (shield)
brown (1)
white (2)
green (3)
2
blank (shield)
brown (1)
white (3)
2
blank (shield)
Kabelbelegung_SE-Sensoren_deu.wmf