Roland R1000 Series Manual page 65

Double sheet detector
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

B0046191 / Rev. 1.12
5.2.5.3
DeviceNet (B-coded)
An M12 plug with inverse coding is used for the DeviceNet connection. A T-connector is not
necessary, because the control unit is equipped with input and output.
The corresponding cable plugs are part of the standard scope of supply.
Input (Pos. B)
M12, 5-pin, B-coded, male connector at control unit
2
1
5
3
4
View:
plug side
Suppliers / types / notes: Binder, type 715 (B-coded) and others
5.2.5.4
DeviceNet (A-coded)
An M12 plug with inverse coding is used for the DeviceNet connection. A T-connector is not
necessary, because the control unit is equipped with input and output.
The corresponding cable plugs are part of the standard scope of supply.
Input (Pos. B)
M12, 5-pin, A-coded, male connector at control unit
2
1
5
3
4
View:
plug side
Suppliers / types / notes: Binder, type 715 (A-coded) and others
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series E20
with integrated fieldbus interface
Note
If the E20 is the last participant in the bus, then an external termination
resistor should be placed into the open connector. The resistor is not
included in the scope of supply.
Allocation of DeviceNet connection
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Note
If the E20 is the last participant in the bus, then an external termination
resistor should be placed into the open connector. The resistor is not
included in the scope of supply.
Allocation of DeviceNet connection
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Manual
Output (Pos. C)
M12, 5-pin, B-coded, female connector at control unit
shield
V +
V -
CAN High
CAN Low
Output (Pos. C)
M12, 5-pin, A-coded, female connector at control unit
Shield
V +
V -
CAN High
CAN Low
Electrical installation
1
2
5
4
3
View:
plug side
1
2
5
4
3
View:
plug side