Communication with the PLC
Bytes 21 - 23:
Octet.bit
PLC -> R1000 (BIN)
21.0
---
21.1
---
21.2
Zero adjust (sensor 4)
21.3
Teach-In 1-sheet (sensor 4)
21.4
---
21.5
---
21.6
---
21.7
---
22.0
---
22.1
---
22.2
---
22.3
---
22.4
---
22.5
---
22.6
---
22.7
---
23.0
---
23.1
---
23.2
---
23.3
---
23.4
---
23.5
---
23.6
---
23.7
---
1)
Ready / ENABLE (via I/O): If 0/0V, then control unit fault. Operator action necessary at the control unit, e.g. memory
fault, voltage missing or too low.
2)
The control unit configuration can be selected 0V active or 24V active for these outputs. This applies also to I/O
outputs.
3)
Sensor selection with E20 via process channel or program data.
4)
The measuring value is spent as follows:
HIGH BYTE (Byte 10 resp. 13, 16, 19, 22 without Bit 6, 7)
1.
Micrometer
2.
1 - 10000 inch
3.
1/10%
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
80
Double Sheet Detector R1000 series E20
with integrated fieldbus interface
=
0...16000µm
-5
=
0...6300 x 10
inch
=
0...9999 1/10%
Manual
R1000 -> PLC (BOUT)
Type of material at sensor 4 (here always 1)
Current measuring program S4: Teach-In performed
---
---
2)
Warning
2)
0-sheet
sensor 4
2)
1-sheet
sensor 4
2)
2-sheet
sensor 4
4)
High byte thickness value
(sensor 4)
---
---
4)
Low byte thickness value
(sensor 4)
Low Byte (Byte 11 resp. 14, 17, 20, 23)
B0046191 / Rev. 1.12