Roland R1000 Series Manual page 48

Double sheet detector
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

Mounting
4.3.2.2
Spring loaded sensor bracket SH75GS
Fig. 22: Spring loaded sensor bracket SH75GS
Pos: 33 /Doppelblech/Sensoren/Sensorhalterungen/Gefederte Sensorhalterung SHS42GS + SHS75GS mit Flachsauger @ 1\mod_1215005515656_501.docx @ 6417 @ 344 @ 1
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
48
Double Sheet Detector R1000 series E20
with integrated fieldbus interface
Ø
10
movable
fixed
Sensor
View in direction "A"
without sensor
10.5
All Dimensions are in mm. Tolerance: ±0.4 mm.
Manual
"A"
20,5
152.5
B0046191 / Rev. 1.12