B0046191 / Rev. 1.12
Fig. 60: Selecting the configuration mode
Available configuration modes:
•
Configuration system parameter
•
Configuration program parameter
•
Data backup
•
Firmware update
System parameters are general adjustments (e.g. language).
Program parameters are application specific adjustments (e.g. input of nominal sheet thickness).
Pos: 59 /Doppelblech/Geräte/E20 Bus/7 Inbetriebnahme/Parameter (Programm-) @ 0\mod_1173276272625_501.docx @ 3234 @ 2 @ 1
7.6
Program parameters
The program parameters contain the information required for the various measurement programs.
For accessing the program parameters, select the mode "configuration program parameter" and
confirm with ENTER.
Program parameter 1: Selecting the measuring program to be configured.
program param.
program number:
Fig. 61: Selecting the program to be configured
Here the measuring program (1-255) to be configured is selected. All following adjustments apply
to the selected program (here: program no. 1).
Program parameter 2: Selecting the sensor to be used for measurement (only for 4P version).
program param.
sensor no.:
Fig. 62: Selecting the sensor
Here the sensor (1 - 4) must be selected, which is to be used for measurement (4P version only).
For this purpose the item "program" must be selected under "sensor selection" in the system
configuration (system parameter 12).
If the sensor selection is made via "program" the sequence measurements are also available.
Thus the following combinations are available:
•
1 / 2 / 3 / 4 / 1+2 / 1+3 / 1+4 / 2+3 / 2+4 / 3+4 / 1+2+3 / 1+2+4 / 1+3+4 / 2+3+4 / 1+2+3+4
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series E20
with integrated fieldbus interface
Note
After exiting the configuration mode the password remains active for five
minutes. Thus other configuration adjustments can be made, without re-
entering the password. If no key is pressed (while in the menu level), then
the program changes to the measurement mode
1
1
2
1
Note
A change of the sensor deletes the values determined during
Teach-In. A new Teach-In is required.
Manual
Start-up
111