Roland R1000 Series Manual page 120

Double sheet detector
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

Start-up
System parameter 14: Adjusting the measuring mode.
system parameter
mode: ext.continuous
Fig. 90: Adjusting the measuring mode
Possible measurement modes:
External continuous measurement:
The system executes measurements, as long as the "Measurement start" signal is applied
via the external PLC input. The repetition rate of the measurement depends on the type of
sensor: 0.5 seconds for P42, P30, P42A, P75V; 1 second for P36; 2 seconds for P75; 7
seconds for P128.
External single measuring:
The system measures once if the "Measurement start" signal is applied via the external PLC
input. Each measurement must initiated separately. The hints in chapter 6.3.2. „timing
diagram single measurement" must be abided by.
Demo mode:
This mode of operation is intended for equipment demonstrations, but not for normal process
operation. The system executes measurements continuously.
The repetition rate of the measurement depends on the type of sensor:
1 second for P42, P30, P42A, P75V; 2 seconds for P36; 4 seconds for P75; 15 seconds for
P128.
System parameter 15: Specifying the system reaction when 2-sheet is detected.
system parameter
hold if 2sheets:
Fig. 91: Adjusting the 2-sheet reaction
Possible choice:
No:
Yes:
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
120
Double Sheet Detector R1000 series E20
with integrated fieldbus interface
14
15
no
The outputs (0-sheet, 1-sheet and 2-sheet) are activated according to the number of
sheets between the sensors. The equipment does not block operation if double
sheet is encountered.
(Currently under preparation) The outputs (0-sheet, 1-sheet and 2-sheet) are
activated according to the number of sheets between the sensors. If double sheet is
detected, the output "2-sheet" is activated and the equipment is blocked until the 2-
sheet condition is cleared.