System parameter 11: Specifying the number of connected sensors (only for 4P unit).
system parameter
number of sensors: 1
Fig. 87: Specifying the number of sensors
Possible choices:
1 sensor
2 sensors
3 sensors
4 sensors
System parameter 12: Specifying the type of actuating the sensors (only for 4P control unit).
system parameter
sel. sensor:
Fig. 88: Sensor selection
Possible choices:
External:
Program:
System parameter 13: not available (reserve).
system parameter
not available
Fig. 89: Reserved system parameter
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series E20
with integrated fieldbus interface
11
Attention
Changing the current configuration will delete all stored program
parameters. Then for all sheet types the nominal thickness values
must be re-entered and the Teach-In must be performed again.
12
ext.
Switching of sensor is accomplished via the external PLC lines
„Sensor selection" A and B.
Advantage: faster sensor switching procedure.
Switching of sensor is accomplished via program selection.
A sensor (sensor sequence) is assigned to each program.
Advantage: less programming effort.