Electrical installation
5.2.5
Fieldbus connection (pos. C1 and C2)
5.2.5.1
Profibus-DP
According to the Profibus-DP Organization (PNO) for the protection class IP67 a round connector
M12 with inverse coding should be used. A "T-Connector" is not necessary, because the control
unit is equipped with input and output connectors.
The corresponding cable plugs are part of the standard scope of supply.
M12, 5-pin, B-coded, male connector at control unit
2
3
View: plug side
5.2.5.2
ControlNet
The control unit has two coaxial fieldbus connections "A" and "B" for ControlNet. For normal
applications one connection can be used, for redundant applications both connections must be
used.
The corresponding cable plugs are not within the scope of supply.
Fieldbus type
ControlNet
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
64
Double Sheet Detector R1000 series E20
with integrated fieldbus interface
Note
If the E20 is the last participant in the bus, then an external terminating
resistor should be placed into the open connector.
The resistor is not included in the scope of supply.
Allocation of Profibus connection (Profibus-DP Slave)
Input (Pos. C2)
1
5
4
Suppliers / types / notes: Binder, type 715 (B-coded) and others
Allocation of ControlNet connector
Manual
M12, 5-pin, B-coded, female connector at control unit
Pin 1
+5V
Pin 2
Line A
Pin 3
GND
Pin 4
Line B
Pin 5
Shield/Earth
1
Connector C1 (ControlNet output)
2
Connector C2 (ControlNet input)
Connector C1 "A"
BNC
B0046191 / Rev. 1.12
Output (Pos. C1)
1
2
5
4
3
View: plug side
Connector C2 "B"
BNC