Roland R1000 Series Manual page 63

Double sheet detector
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

B0046191 / Rev. 1.12
5.2.4
Connection of Optocoupler outputs and RSI interface (pos. B1 and B2)
The RSI enables the operation of future ROLAND sensors which have not only the signal output
but also the RSI interface.
On the following pages the pin configuration of the optocoupler outputs and the RSI (ROLAND
serial interface) are described.
Connector at control unit
Optocoupler output
1
7
8
6
5
View: plug side
RSI
1
5
4
View: plug side
Table: Pin configuration of optocoupler output and RSI interface
Optocoupler outputs for fast switching operation
For reasons of velocity and for diagnostic purposes it could be useful to issue the relevant
switching signal 0-sheet, 1-sheet, 2-sheet via a real-time interface. Latency periods and cycle times
of fieldbus communications are eliminated.
Signal
OUT0
OUT1
OUT2
OUT3
OUT4
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series E20
with integrated fieldbus interface
Note
The Optocoupler inputs are placed at the supply voltage connection
(pos. G)
M8, 8-pin, A-coded, female
connector at control unit
pin 1
pin 2
pin 3
2
3
pin 4
4
pin 5
pin 6
pin 7
pin 8
M12, 5-pin, A-coded, female
connector at control unit
pin 1
2
pin 2
pin 3
3
pin 4
pin 5
Meaning
0-sheet
1st optocoupler output
1-sheet
2nd optocoupler output
2-sheet
3rd optocoupler output
Enable
4th optocoupler output
Warning
5th optocoupler output
Manual
+24VDC
OUT0
OUT1
OUT2
OUT3
OUT4
-
Shield / ground
Internal at enclosure (common)
Shield / ground
Internal at enclosure (common)
-
GND
RSI- High
RSI- High
Notes
Electrical installation
Manufacturer / types / notes
Binder type 713 and others
External supply 24V DC
1st optocoupler output
2nd optocoupler output
3rd optocoupler output
4th optocoupler output
5th optocoupler output
Binder type 713 and others