Electrical installation
5.2.5.5
CanOpen
An M12 plug with inverse coding is used for the CanOpen connection. A T-connector is not
necessary, because the control unit is equipped with input and output.
The corresponding cable plugs are part of the standard scope of supply.
Input (Pos. B)
M12, 5-pin, B-coded, male connector at control unit
2
1
5
3
4
View:
plug side
5.2.5.6
Interbus-S
The corresponding cable plugs are part of the standard scope of supply.
Input (Pos. C2, male connectors)
Male contacts at the control unit (male socket)
2
5
3
View:
plug side
The module supports 500 kbit/s operation. The corresponding cable plugs are part of the standard
scope of supply.
5.2.5.7
ProfiNet IO
The ProfiNet IO connection is implemented as 1-Port.
Round-shape connector, M12, 4-pin., D-coded,
socket contact at control unit (Pos. C2)
2
1
3
4
View:
Plug side
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
66
Double Sheet Detector R1000 series E20
with integrated fieldbus interface
Note
If the E20 is the last participant in the bus, then an external termination
resistor should be placed into the open connector. The resistor is not
included in the scope of supply.
Allocation of CanOpen connection
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Suppliers / types / notes: Binder, type 715 (B-coded) and others
Allocation of Interbus-S connection
M12, 5-pin, B-coded,
pin 1
pin 2
1
pin 3
4
pin 4
pin 5
Plug enclosure
Allocation of ProfiNet IO connection
Pin 1
Pin 2
Pin 3
Pin 4
Plug enclosure
The corresponding cable plugs are part of the standard scope of supply.
Manual
M12, 5-pin, B-coded, female connector at control unit
shield
n. a.
GND
CAN_H
CAN_H
Output (C1, female connectors)
Female contacts at the control unit (female socket)
DO
/DO
1
5
DI
4
/DI
GND
View:
shield
plug side
TD +
RD +
TD –
RD –
Shield
B0046191 / Rev. 1.12
Output (Pos. C)
1
2
5
3
4
View:
plug side
M12, 5-pin, B-coded
pin 1
2
pin 2
pin 3
3
pin 4
pin 5
Plug enclosure
DO
/DO
DI
/DI
GND
shield