Roland R1000 Series Manual page 114

Double sheet detector
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

Start-up
Program parameter 7: Teach-in
program param.
teach-in:
Fig. 69: Status of Teach-in
Possible choices:
off:
on:
For performing a teach-in, select "on" and press the ENTER key (if no teach-in was done or if a
teach-in has to be repeated).
Then the operator is requested to attach a sheet with the nominal thickness:
program param.
attach sheet !!
Fig. 70: Request for attaching a sheet
After having attached a sheet press the ENTER key.
During the teach-in procedure the Teach-in value is displayed:
program param.
TI value:
Fig. 71: Teach-in measurement value
This measured value can be accepted or changed, e.g. to calibrate the control unit.
The Teach-in procedure is now completed.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
114
Double Sheet Detector R1000 series E20
with integrated fieldbus interface
7
on
A teach-in has not been executed
A teach-in will now be performed
7
Attention
A sheet without air gap must be attached to the sensor. The position
of the sheet during teach-in must be the same as for normal
operation. Otherwise the measurement result could be faulty.
7
0.97 mm
Attention
For a 4P system with sequential measurement the entire teach-in
procedure for all sensors is performed in the selected sequence. For
sensor selection A/B the teach-in for the selected sensor is then
competed. However, if all sensors should be taught, then the teach-in
of the other sensors must be repeated separately.
Manual